Sintec Optronics offer various types of fiber instruments, such as interferometric inspection system, encircled flux meter, fiber shaker, fiber glass geometry measurement system, FGC-GA array geometry measurement system, and etc.

Product Introduction

Interferometric Inspection System

The interferometric inspection system (STAR-VFI-xxxx) specifically designed for checking the surface quality and flatness of your cleaved or polished fibers. The VFI interferometer has proved itself in Research, Production and QA over and over and the feedback we get from users indicates that they value these features:

Features & Benefits

Applications

Specifictions

 

STAR-VFI-200

STAR-VFI-1200

STAR-VFI-2000

Field of View

200µm

1200µm maximum with x1.5, x2, x3, and x6 digital zoom

2000µm maximum with x1.5, x2, x3, and x6 digital zoom

Dimensions

240mm(W)x240mm(D) x90mm(H)

Weight

2.0kg

Image Sensor

1/1.8 inch CMOS array, 12bit, 6.4MP

Effective Pixels

2076x2076, 2.4µm square pixels

Fringe Resolving Power

2µm/fringe

Max frame rate

> 20 fps

LED wavelength

587nm

Accuracy up to 2 deg

< 0.1 deg

Accuracy up to 10 deg

< 0.2 deg

Image Format

12-bit png

Connection to computer

USB 3.0 (USB Type C to USB type A: 1m cable)

Power Supply

12V in-line power supply

Operating Temp.

0oC to + 50oC

Humidity

5%- 95% relative, non-condensing

5%- 95% relative, non-condensing

Operating systems

Windows7/8/10 64bit only

Hardware

2GB RAM; USB 3.0 port; 64bit

Ordering Information

Part number

Description

STAR-VFI-200

Interferometric inspection system for fibers with diameters of 125µm. Includes STAR-VFI-200 optical unit; STAR-VFI-H0 fiber holder for 125µm fibers; PC software; USB cable; power supply. Computer not included.

STAR-VFI-1200

Interferometric inspection system for fibers with diameters from 125 to 1200µm. Includes STAR-VFI-1200 optical unit; STAR-VFI-H0/0400 fiber holder for 400µm fibers; STAR-VFI-FTK400 fiber samples; PC software; USB cable; power supply.

Computer not included.

STAR-VFI-2000

Interferometric inspection system for fibers with diameters from 400 to 2000μm. Includes STAR-VFI-2000 optical unit; STAR-VFI-H0/0400 fiber holder for 400μm fibers; STAR-VFI-FTK400 fiber samples; PC software; USB cable; power supply.

Computer not included.

Options

Options

Description

STAR-VFI-H0

fiber holder for 125µm fiber, perpendicular cleave

STAR-VFI-H0-200

fiber holder for 200µm fiber, perpendicular cleave

STAR-VFI-H0-400

fiber holder for 400µm fiber, perpendicular cleave

STAR-VFI -H0-600

fiber holder for 600µm fiber, perpendicular cleave

STAR-VFI -H0-800

fiber holder for 800µm fiber, perpendicular cleave

STAR-VFI -H0-1000

fiber holder for 1000µm fiber, perpendicular cleave

STAR-VFI -H0-1250

fiber holder for 1250µm fiber, perpendicular cleave

STAR-VFI -H0-1500

fiber holder for 1500µm fiber, perpendicular cleave

STAR-VFI -H0-2000

fiber holder for 2000µm fiber, perpendicular cleave

STAR-VFI -H0-1250F

fiber holder for 1.25mm ferrules

STAR-VFI -H0-1500F

fiber holder for 2.5mm ferrules

STAR-VFI -H0-2000F

fiber holder for 3.2mm ferrules

STAR-VFI -H-Angle

angle inducing anulus for measuring cleave angles from 4° – 12°

STAR-VFI -MPS

VFI mounting plate for standard Arden Photonics VFI holders

STAR-VFI -MPF

VFI mounting plate for 125µm Fujikura style fiber holders (also works with FGC holders)  

STAR-VFI -MPFL

VFI mounting plate for 200µm+ Fujikura style fiber holders (also works with FGC holders)

STAR-VFI -CC-01

Rigid carrying case for STAR-VFI-200, STAR-VFI-1200, STAR-VFI-2000

STAR-VFI –UEW2

extended warranty covering parts and labour for 2 years from purchase, return to base. Cover excludes camera.

STAR-VFI -UEW3

extended warranty covering parts and labour for 3 years from purchase, return to base. Cover excludes camera.

STAR-VFI –UEW3

extended warranty covering parts and labour for 4 years from purchase, return to base. Cover excludes camera.

STAR-VFI -UEW5

extended warranty covering parts and labour for 5 years from purchase, return to base. Cover excludes camera.

STAR-VFI -FTK400

fiber samples, 400µm diameter, for checking STAR-VFI-1200 alignment and calibration

Encircled flux meter

Encircled Flux is now widely accepted as the preferred way to specify modal filling by IEEE, TIA and IEC. Measurement of Encircled Flux is defined in FOTP-203 – the “Modal Explorer” is the most standards-compliant measurement system available today and has been chosen by major standards labs in the USA and Europe as the basis for their critical measurements

Its compact size and solid design make it the tool of choice in cable makers, fiber optic instrument companies and VCSEL, laser and LED source makers. In use in factories every day, major players in the industry rely on the Modal Explorer.The Modal Explorer is available for measurements at 850 and 1300nm as well as other custom wavelengths. Modal Explorer makes measurement of Encircled Flux easy and accurate, and it complies with international standards.

But if you are measuring laser-based transmission light sources for multi-mode systems you may need to use a test jumper assembly and fiber shaker in order to avoid “speckle”. Industry standards, for example IEEE 802.3aq and FOTP–203, call for the use of a mechanical fiber shaker. The Fiber Shaker (MPX-SR3 option) reduces speckle by changing the differential path length of the modes in the fiber. The fiber is shaken continuously to allow the speckle to be averaged out. This will ensure sufficient repeatability for the measurement of the Encircled Flux

Features & Benefits

Applications

MPX-CP01                                                                           MPX-CC-02

Specifictions

 

STAR-MPX-1

STAR-MPX-2

Wavelength

850nm (Encircled Flux measurement range is from 400nm to 1100nm but End Face Inspecton and Focussing is at 850nm)

1300nm (Encircled Flux measurement range is from 900nm to 1700nm but End Face Inspecton and Focussing is at 1300nm)

Size

260mm(W)x270mm(D)x90mm(H)

10”(W)x10.5”(D)x3.5”(H)

260mm(W)x390mm(D)x110mm(H)

10”(W)x15”(D)x4.5”(H)

Weight

2.5kg / 5.5lb

7.0kg / 15.5lb

Dynamic Range

60dB

>60dB

Image Sensor

CCD array, 12 bit, 4.65µm square pixels

InGaAs array, 12 bit, 30µm square pixels

Maximum Core Diameter

110µm

110µm

Maximum source power

Approx 10mW (depends on power density, fiber type etc.)

Approx 10mW (depends on power density, fiber type etc.)

Input connector adaptors available

Universal 2.5mm ferrule; LC (both supplied as standard), FC, ST,SC,MTP,Bare fiber (optional)

Universal 2.5mm ferrule; LC (both supplied as standard), FC, ST,SC,MTP,Bare fiber (optional)

End Face Inspection and Focussing

850nm LED

1300nm LED

Built0in reference source

850nm LED, FC connector, over-filled (110um core diameter,; 0.37NA)

1300nm LED, FC connector, over-filled (110um core diameter,; 0.37NA)

Power

External switched mode power supply (supplied)

External switched mode power supply (supplied)

Connection to Computer

USB 2.0 (USB B to USB A: 2m cable supplied)

USB 2.0 (USB B to USB A: 3m cable supplied)

Computer Requirements (minimum)

2GB RAM; USB 2.0 port – note system will not work with USB 3.0

2GB RAM; USB 2.0 port – note system will not work with USB 3.0

Operating System supported

Windows7/8/10 32bit or 64bit

Windows7/8/10 32bit or 64bit

Operating Temperature

0oC to + 50oC

0oC to + 50oC

Humidity

5%- 95% relative, non-condensing

5%- 95% relative, non-condensing

Ordering Information

Part number

Description

MPX1

MPX-1 system for modal analysis of multimode fibers at 850nm, including optical unit, cables, software package and user manual. System is supplied with a universal 2.5mm connector adaptor and an LC connector adaptor. Computer not included. See product specification for information about computer configuration.

MPX2

MPX-2 system for modal analysis of multimode fibers at 1300nm, including optical unit, cables, software package and user manual. System is supplied with a universal 2.5mm connector adaptor and an LC connector adaptor. Computer not included. See product specification for information about computer configuration

Options

Option

Description

MPX-API

MPX API software add on, designed for accessing and controlling the MPX for automated testing (additional license required)

MPX-CC-01

Rigid carrying case for MPX-1

MPX-CC-02

Rigid carrying case for MPX-2

MPX-CP01

Chrome-on-Glass calibration artefact and software package for MPX-1 and MPX-2 to enable user calibration traceable to NPL standards. Includes Chrome-on-Glass artefact, software CD and operation instructions

MPX-CAU250

Input connector adaptor for 2.5mm diamter ferrule connectors, universal (supplied as standard with MPX-1 and MPX-2)

MPX-CALC

Input connector adaptor for LC connectors (supplied as standard with MPX-1 and MPX-2)

MPX-CAFC

Input connector adaptor for FC connectors

MPX-CAFC/APC

Input connector adaptor for FC/APC connectors

MPX-CASC

Input connector adaptor for SC connectors

MPX-CASC/APC

Input connector adaptor for SC/APC connectors

MPX-CAST

Input connector adaptor for ST connectors

MPX-CAMTP

Input connector adaptor for MTP connectors

MPX-CAMTRJ

Input connector adaptor for MTRJ connectors

MPX-CAU250/APC

Input connector adaptor for 2.5mm diameter ferrule APC connectors, universal

MPX-SR3***

Fiber shaker with 2 fibers (1 x OM1 and 1 x OM2); FC/PC connectors on input and output. ***See the description on the next page

MPX-UEW3

MPX extended warranty covering parts and labour for 3 years from purchase, return to base. Cover excludes camera

APL-LC

Laptop computer, pre-installed with application software

APL-DC

Desktop computer, pre-installed with application software

Fiber shaker (***see option MPX-SR3)

Fiber types

OM1 (62.5/125 GI) and OM2 (50/125 GI)

Input & Output Connectors

FC/PC

Frequency of shaking

10Hz

Insertion loss

<1dB

Size

260mm(W)x270mm(D)x90mm(H)

Weight

1.9kg

Power

External switched mode power supply. Requirements: 90-240V, <500mA, <50W

Operating Temperature

+5oC to +40oC

Storage Temperature

-10oC to +50oC

Fiber Glass Geometry Measurement System

The FGC range is the complete solution for measuring the dimensions of standard and specialty fiber in both production and R&D environments. FGC-GT – fiber glass geometry for fibers up to 400 µm diameter. FGC-GS – fiber glass geometry for fibers up to 1000 µm diameter.

Darkfield Illumination

The darkfield illumination system allows the software to show a clear live image of the end face of the fiber by illuminating the end face of the fiber and imaging the reflected light. This allows users to inspect the end face of the fiber whilst taking geometry measurements. The darkfield method of fiber geometry measurement is supported by both NPL in the UK and NIST in the USA.

The FGC comes with an efficient software package containing controls to switch between reflection and transmission mode. This allows users to quickly and easily get both core and cladding geometry measurements including diameter, non-circularity and concentricity. The software contains measurement templates for all standard telecoms fibers, however users can also create their own. This allows the measurement of many special fiber types including dual clad fiber, bend insensitive fiber, multicore fibers and many more.

Features & Benefits

Specifictions

 

FGS-GT*

FGC-GS**

Optical

 

 

Max field of View

600 µm

1200 µm

Fiber Illumination – Reflection

Darkfield illumination, 850nm LED

Fiber Illumination - Transmission

Mulitple LED array, 850nm

Repeatability

Single mode

Multi mode

Multi mode

Core Diameter

< 0.05 µm

< 0.08 µm

< 0.1 µm

Cladding Diameter

< 0.05 µm

< 0.05 µm

< 0.25 µm

Core Non-circularity

< 1.0%

< 0.5%

< 0.05%

Cladding Non-circularity

< 0.1%

< 0.1%

< 0.1%

Core-to-Cladding Concentracity

< 0.06 µm

< 0.05 µm

< 0.05 µm

Measurement Capability

Measurement Time

< 10 seconds (excluding fiber prep)

Fiber Diameter

Up to 400 µm

Up to 1000 µm

Special Fibers

Dual clad, octagonal, PM, Multicore, PCF, etc.

Physical

Weight

11kg ( with carry case 33kg)

Size

0.5 x 0.5 x 0.2

Operating Temp

0oC to + 50oC

Humidity

5%- 95% relative, non-condensing

Computer Requirements

All FGC systems are supplied with a desktop computer running up-to-date windows operating system

Data Interface

2 x USB3.0 (USB B to USB A: 2m cable supplied)

Ordering Information

Part number

Description

FGC-GT

Fiber Glass Geometry System for measurement of optical fibers with diameters up to 400 µm. Including optical unit, fiber handling bench, cables, software package; desktop computer; pair of Arden holders suitable for 250 µm diameter coated fiber.

FGS-GS

Fiber Glass Geometry System for measurement of optical fibers with diameters up to 1000 µm. Including optical unit, fiber handling bench, cables, software package; desktop computer; pair of Arden holders suitable for 400 µm diameter coated fiber.

FG-H-250

Pair of Arden FGC fiber holders with 250 µm V-groove, suitable for 250 µm diameter coated fiber

FG-H-400

Pair of Arden FGC fiber holders with 400 µm V-groove, suitable for 400 µm diameter coated fiber

FG-H-600

Pair of Arden FGC fiber holders with 600 µm V-groove, suitable for 600 µm diameter coated fiber

FG-H-800

Pair of Arden FGC fiber holders with 800 µm V-groove, suitable for 800 µm diameter coated fiber

FG-H-1000

Pair of Arden FGC fiber holders with 1000 µm V-groove, suitable for 1000 µm diameter coated fiber

FG-H-CUST

Pair of Arden FGC fiber holders with customer defined V-groove diameter

FGC-GUEW3

FGC-Glass geometry system, extended warranty covering parts and labour for 3 years from purchase, return to base. Cover excludes camera.

FGC-GUEW5

FGC-Glass geometry system, extended warranty covering parts and labour for 5 years from purchase, return to base. Cover excludes camera.

FGC-PMI

PM illuminator designed for use with the FGC

FGC-GA Array Geometry Measurement System

The FGC-GA is the ultimate solution for measurement and process control for V-groove array production. With one unit, users can measure V-groove block geometry, core-to-core pitch and core X & Y offset of multifiber arrays up to 15mm in width. With a 1200µm field of view as well as an automated lateral stage for scanning along the entire width of the array, the FGC-GA is the fastest and most flexible way to produce top quality V-groove arrays

Features and Benefits

Specifications

Optical

Optical FGC-GA

Repeatability

Core X/Y-offsets* < 0.1 µm

Core-core Distance* < 0.1 µm

Measurement Capability

Measurement Time < 1 minute (excluding fiber preparation) for a 3-fiber array

Array Width Up to 15mm

Fiber Types Singlemode, Multimode, PM

Physical

Weight 13kg (with carry case 44kg)

Size 0.5m x 0.5m x 0.2m

Operating Temperature 0 – 50° C

Humidity 5% – 95%, relative, non-condensing

Data Interface 3 X USB 3.1 (USB B to USB A: 0.5m cable supplied)

Computer Requirements All FGC systems are supplied with a desktop computer

running up-to-date Windows operating system

Max Field of View

1200µm

Fiber Illumination – Reflection

Multichannel 525nm

 

Fiber Illumination – Transmission

Darkfield illumination, 525nm LED

 

ODTR Launch boxes

When measuring fiber optic cables using an OTDR, a launch box (also known as a Dead Zone Eliminator) helps to minimize the effects of the OTDR’s launch pulse thus improving the accuracy of the measurement. Our high quality launch boxes come in three different housing formats:

  1. Rugged “PELI” boxes versions are airtight, watertight and incredibly tough. These military approved cases are IP65 rated and are used in the harshest environments. Select this version if you want the best protection for your lead-in fiber.
  2. Aluminium “EuroCard” enclosure is smaller, lighter than the PELI case offering an ideal solution for factory or lab environments where space is at a premium.
  3. ABS “Midi”style enclosure is slightly larger than the “Euro” for longer fiber lengths.

We can supply a range of products in different fiber types including versions with “ModCon” mode control to enable your OTDR to meet the Encircled Flux launch condition requirement in IEC 61280-4-1.

All our boxes come with a full test certificate and 1 year warranty (except damaged connectors)

We offer a standard range of products but we also have the capability to make custom solutions to your precise requirements.

Features & Benefits

Applications

Specification

 

“PELI” style

“Midi” style

“EuroCard” style

Size

232 x 192 x 111 mm
9.25 x 7.75 x 4.5 in

155 x 240 x 35 mm
6.0 x 9.5 x 1.45 in

166 x 105 x 33 mm
6.5 x 4.1 x 1.3 in

Weight

1.3 kg (3.0 lb)

0.5kg (1.1 lb)

0.5kg (1.1 lb)

Operating temperature

-40 to +55 C

0 to +40 C

0 to +40 C

Typical loss

< 0.5dB @ 1310nm with 1km sm fiber

< 0.5dB @ 1310nm with 1km sm fiber

< 1.0dB @ 1310nm with 200m mm fiber

Input and output lead length

1m

1m

1m

Image

Ordering information

We offer OTDR launch boxes in several standard configurations:

OTDR lead-in boxes in “PELI” case – singlemode

Part number

Description

ALB-09-0500-FC/FC-P

OTDR lead-in box, containing 500m of 09/125 fiber with FC connectors, in “Peli” case.

ALB-09-0500-FCAPC/FCAPC-P

OTDR lead-in box, containing 500m of 09/125 fiber with FCAPC connectors, in “Peli” case.

ALB-09-0500-SC/SC-P

OTDR lead-in box, containing 500m of 09/125 fiber with SC connectors, in “Peli” case.

ALB-09-0500-SCAPC/SCAPC-P

OTDR lead-in box, containing 500m of 09/125 fiber with SCAPC connectors, in “Peli” case.

ALB-09-1000-FC/FC-P

OTDR lead-in box, containing 1000m of 09/125 fiber with FC connectors, in “Peli” case.

ALB-09-1000-FCAPC/FCAPC-P

OTDR lead-in box, containing 1000m of 09/125 fiber with FCAPC connectors, in “Peli” case.

ALB-09-1000-SC/SC-P

OTDR lead-in box, containing 1000m of 09/125 fiber with SC connectors, in “Peli” case.

ALB-09-1000-SCAPC/SCAPC-P

OTDR lead-in box, containing 1000m of 09/125 fiber with SCAPC connectors, in “Peli” case.

ALB-09-2000-FC/FC-P

OTDR lead-in box, containing 2000m of 09/125 fiber with FC connectors, in “Peli” case.

ALB-09-2000-FCAPC/FCAPC-P

OTDR lead-in box, containing 2000m of 09/125 fiber with FCAPC connectors, in “Peli” case.

ALB-09-2000-SC/SC-P

OTDR lead-in box, containing 2000m of 09/125 fiber with SC connectors, in “Peli” case.

ALB-09-2000-SCAPC/SCAPC-P

OTDR lead-in box, containing 2000m of 09/125 fiber with SCAPC connectors, in “Peli” case.

OTDR lead-in boxes in “MIDI” case – singlemode

Part number

Description

ALB-09-0500-FC/FC-M

OTDR lead-in box, containing 500m of 09/125 fiber with FC connectors, in “MIDI” case.

ALB-09-0500-FCAPC/FCAPC-M

OTDR lead-in box, containing 500m of 09/125 fiber with FCAPC connectors, in “MIDI” case.

ALB-09-0500-SC/SC-M

OTDR lead-in box, containing 500m of 09/125 fiber with SC connectors, in “MIDI” case.

ALB-09-0500-SCAPC/SCAPC-M

OTDR lead-in box, containing 500m of 09/125 fiber with SCAPC connectors, in “MIDI” case.

ALB-09-1000-FC/FC-M

OTDR lead-in box, containing 1000m of 09/125 fiber with FC connectors, in “MIDI” case.

ALB-09-1000-FCAPC/FCAPC-M

OTDR lead-in box, containing 1000m of 09/125 fiber with FCAPC connectors,in “MIDI” case.

ALB-09-1000-SC/SC-M

OTDR lead-in box, containing 1000m of 09/125 fiber with SC connectors, in “MIDI” case.

ALB-09-1000-SCAPC/SCAPC-M

OTDR lead-in box, containing 1000m of 09/125 fiber with SCAPC connectors,in “MIDI” case.

ALB-09-2000-FC/FC-M

OTDR lead-in box, containing 2000m of 09/125 fiber with FC connectors, in “MIDI” case.

ALB-09-2000-FCAPC/FCAPC-M

OTDR lead-in box, containing 2000m of 09/125 fiber with FCAPC connectors,in “MIDI” case.

ALB-09-2000-SC/SC-M

OTDR lead-in box, containing 2000m of 09/125 fiber with SC connectors,in “MIDI” case.

ALB-09-2000-SCAPC/SCAPC-M

OTDR lead-in box, containing 2000m of 09/125 fiber with SCAPC connectors, in “MIDI” case.

OTDR lead-in boxes in “PELI” case – multimode

Part number

Description

ALB-50-100-SC/SC-P

OTDR lead-in box, containing 100m of 50/125 multimode fiber with SC connectors, in “Peli” case.

ALB-50-100-SC/SC-P-MC

OTDR lead-in box, containing 100m of 50/125 multimode fiber with SC connectors, in “Peli” case. With “ModCon” mode controller.

ALB-50-250-SC/SC-P

OTDR lead-in box, containing 250m of 50/125 multimode fiber with SC connectors, in “Peli” case.

ALB-50-250-SC/SC-P-MC

OTDR lead-in box, containing 250m of 50/125 multimode fiber with SC connectors, in “Peli” case. With “ModCon” mode controller.

ALB-50-500-SC/SC-P

OTDR lead-in box, containing 500m of 50/125 multimode fiber with SC connectors, in “Peli” case.

ALB-50-500-SC/SC-P-MC

OTDR lead-in box, containing 500m of 50/125 multimode fiber with SC connectors, in “Peli” case. With “ModCon” mode controller.

ALB-62-100-SC/SC-P

OTDR lead-in box, containing 100m of 62.5/125 multimode fiber with SC connectors, in “Peli” case.

ALB-62-100-SC/SC-P-MC

OTDR lead-in box, containing 100m of 62.5/125 multimode fiber with SC connectors, in “Peli” case. With “ModCon” mode controller.

ALB-62-250-SC/SC-P

OTDR lead-in box, containing 250m of 62.5/125 multimode fiber with SC connectors, in “Peli” case.

ALB-62-250-SC/SC-P-MC

OTDR lead-in box, containing 250m of 62.5/125 multimode fiber with SC connectors, in “Peli” case. With “ModCon” mode controller.

ALB-62-500-SC/SC-P

OTDR lead-in box, containing 500m of 62.5/125 multimode fiber with SC connectors, in “Peli” case.

ALB-62-500-SC/SC-P-MC

OTDR lead-in box, containing 500m of 62.5/125 multimode fiber with SC connectors, in “Peli” case. With “ModCon” mode controller.

OTDR lead-in boxes in “EuroCard” enclosure – multimode

Part number

Description

ALB-50-100-SC/SC-E

OTDR lead-in box, containing 100m of 50/125 multimode fiber with SC connectors, in “EuroCard” case.

ALB-50-100-SC/SC-E-MC

OTDR lead-in box, containing 100m of 50/125 multimode fiber with SC connectors, in “EuroCard” case. With “ModCon” mode controller.

ALB-50-250-SC/SC-E

OTDR lead-in box, containing 250m of 50/125 multimode fiber with SC connectors, in “EuroCard” case.

ALB-50-250-SC/SC-E-MC

OTDR lead-in box, containing 250m of 50/125 multimode fiber with SC connectors, in “EuroCard” case. With “ModCon” mode controller.

ALB-50-500-SC/SC-E

OTDR lead-in box, containing 500m of 50/125 multimode fiber with SC connectors, in “EuroCard” case.

ALB-50-500-SC/SC-E-MC

OTDR lead-in box, containing 500m of 50/125 multimode fiber with SC connectors, in “EuroCard” case. With “ModCon” mode controller.

ALB-62-100-SC/SC-E

OTDR lead-in box, containing 100m of 62.50/125 multimode fiber with SC connectors, in “EuroCard” case.

ALB-62-100-SC/SC-E-MC

OTDR lead-in box, containing 100m of 62.5/125 multimode fiber with SC connectors, in “EuroCard” case. With “ModCon” mode controller.

ALB-62-250-SC/SC-E

OTDR lead-in box, containing 250m of 62.5/125 multimode fiber with SC connectors, in “EuroCard” case.

ALB-62-250-SC/SC-E-MC

OTDR lead-in box, containing 250m of 62.5/125 multimode fiber with SC connectors, in “EuroCard” case. With “ModCon” mode controller.

ALB-62-500-SC/SC-E

OTDR lead-in box, containing 500m of 62.5/125 multimode fiber with SC connectors, in “EuroCard” case.

ALB-62-500-SC/SC-E-MC

OTDR lead-in box, containing 500m of 62.5/125 multimode fiber with SC connectors, in “EuroCard” case. With “ModCon” mode controller.

Other configurations available on application

Reference Fiber Optic Cables

We can supply a wide range of reference patchcords for use as the launch point for optical system testing. These  patchcords are made to the highest tolerances to give you consistent measurement data.

Features & Benefits

Connectors

Connectors

E-2000

FC

LC

SC

SMA

ST

Military termini

Polish

UPC APC

UPC APC

UPC APC

UPC APC

IPC

UPC

UPC

Type

Push   pull

Screw on

Push pull

Push pull

Screw on

Bayonet

Insert

Fibers

Fibre

SMF-28E

PM 850

PM 1300

PM 1550

SX + laser optimised

Infinicor 600

Infinicor 300

Mode field (Core) diameter (µm)

8.2

6.6

9.5

10.5

50

50

62.5

Wavelength (nm)

1310 1550

980 1060

1300

1550

850 1300

850 1300

850 1300

Attenuation (dB/km)

0.35 0.22

3.0

1.0

0.5

2.4 0.8

2.5 0.8

3.0 0.7

Numerical Aperture

0.14

0.14

0.14

0.14

0.20

0.20

0.275

Cables

OD

900um tight

900um loose

1.6mm PVC

1.6mm steel

3mm PVC tight

3mm PVC loose

Jacket material

PVC

Hytrel (nylon) or PTFE (Teflon)

PVC

Stainless steel

PVC

PVDF + PVC

Strength member

Kevlar

Stainless steel

Kevlar

Kevlar

Performance

Fibre

Singlemode

PM

Multimode

Insertion loss (dB)

<0.1

<0.1

<0.05

Return loss (dB)

APC >70 ; PC >55

UPC >55

PC >50

Fibre core eccentricity

<0.5

<0.5

<0.5

Extinction ratio

30

Radius of curvature (mm)

APC 8 < ROC < 12

APC 8 < ROC < 12

APC 8 < ROC < 12

Apex offset (µm)

<30

<30

<30

Fibre height (protrusion) (nm)

-50 FH < +50

-50 FH < +50

-50 FH < +50

 

Share: